Skip to hardware content
VICEPULSEGAMES. GUIDES. GEAR. REPAIR, UNDERSTOOD.
PLAYSTATION 5 / LAYER 04

Enclosed power-supply module

Specialist serviceOriginal Disc Edition · CFI-10xxA

Replace the enclosed module only after a technician confirms the power fault.

Confirm your revision

Read the CFI model on the console label before opening. These internal guides target the 2020 Disc Edition (CFI-10xxA).

CFI-11xx, CFI-12xx, Slim CFI-20xx and Pro CFI-70xx have different internal layouts. Do not transfer screw maps or drive procedures between revisions. Sony’s M.2 reference includes separate model instructions.

DIAGNOSIS & SERVICE ROUTE

Replace the enclosed module only after a technician confirms the power fault.

Signs to investigate

  • No power after outlet and cable checks
  • Physical damage to the power module

Prepare your bench

  • Plastic opening pick
  • Non-metallic spudger
  • Organised screw tray
  • TR8 security Torx driver
  • Phillips screwdriver

Access first

Complete these access guides before the component-specific notes below.

Diagnose, isolate, then service

  1. 01

    Test the outlet and an appropriate known-good power cable before blaming the supply.

  2. 02

    Unplug the console. A technician should follow the matched case-removal sequence and separate the enclosed module from its board contacts.

  3. 03

    Match the supply’s exact revision and connector arrangement. Keep its metal enclosure closed.

  4. 04

    Restore all shielding, insulation and fasteners before reconnecting the console for testing.

STOP POINT

Never open the PSU enclosure or probe its mains circuitry. Unplugging does not make its internal capacitors safe.

BEFORE YOU CALL IT DONE

The fully closed console boots and remains stable during a normal game session.

Restore all covers, shielding and cable routing before powered tests. Keep each screw in its original position. If fit or resistance changes, reopen and inspect rather than tightening harder.

Technical reference & evidence

Original notes by VICEPULSE, checked against the reference below. These are concise component notes; use the matched photographic reference for exact fastener locations and connector details. The AI-generated product render is illustrative, not a service drawing.

iFixit original repair guide ↗

Source-checked on 31 October 2026. VICEPULSE has not bench-tested this procedure. Internal part fit must be verified against your actual revision.